Model: 1kva/2kva/3kva/6kva/10kva/15kva/20kva
Application:
Servers, Data-center, Critical network devices, Sensitive electrionic equipment, Telecom...
Key Feature:
1). Ture on-line double conversion technology with advanced microprocessor control
2). Wide input voltage range
3). Zero transfer time
4). Protection against all type of power problems
5). Self test while start of the UPS
6). Site wiring fault warning
7). On-battery power-on function
8). Smart RS232 communication interface
9). Intelligent slot available
10). Sealed lead-acid, maintenance free battery
Specfications:
Model |
|
C1K |
C2K |
C3K |
C1KS |
C2KS |
C3KS |
Capacity |
VA/W |
1KVA/0.7KW |
2KVA/1.4KW |
3KVA/2.1KW |
1KVA/0.7KW |
2KVA/1.4KW |
3KVA/2.1KW |
Input |
Nominal voltage |
110/115/120VAC or 220/230/240VAC |
Voltage range |
180~300VAC |
Frequency range |
50Hz: 46~54Hz; 60Hz: 56~64Hz |
Phase |
Single phase |
Power factor |
> 97% |
Connection |
IEC320-10A |
IEC320-10A |
IEC320-16A |
IEC320-10A |
IEC320-10A |
IEC320-16A |
Output |
Voltage |
110/115/120VAC x(1+/-2%) or 220/230/240VAC x(1+/-2%) |
Frequency |
Synchronization range(line mode); 50 or 60 x(1+/-0.2%)Hz (Battery mode) |
Phase |
Single phase |
Wave form |
Sine wave |
Power factor |
0.7 |
Voltage distortion |
3% |
4% |
4% |
3% |
4% |
4% |
Overload capability |
110%-150% for 30sec. ≥ 150% for 200ms |
Current crest ratio |
3: 1 |
Connections |
IEC320*4 |
IEC320*6 |
IEC320*3 |
IEC320*4 |
IEC320*6 |
IEC320*3 |
Battery |
Type |
Sealed, maintenance free, lead-acid |
Nominal
DC voltage |
|
|
|
36VDC |
96VDC |
96VDC |
Quantity |
3pcs |
8pcs |
8pcs |
Depends on the requested back-up time |
Back-up time(full load) |
5min |
9min |
5min |
Depends on the capacity of the external battery bank |
Recharge time |
5hrs to 90% if capacity |
Depends on the capacity of the external battery bank |
Automatic transfer |
On overload and UPS failure |
Before UPS
power on |
Default " ON' user adjustable to ' YES" |
Voltage range |
40~132VAC(default), user adjustable within 40~143VAC or 80~264VA(default), user adjustable within 80~286VAC |
Transfer time |
AC to DC
zero |
Inverter to bypass 4ms(typical) |
Indicator |
LED display |
Load level/Battery level, Battery, Utility power, Inverter, Bypass, Overload, Fault |
LCD display |
UPS status 1/P 0/P voltage frequency, Battery voltage, Battery capacity, loading, Temperature, History record |
Audible alarm |
|
Bypass, On battery mode, Battery low, Overload, Fault etc |
Acoustic noise |
At 1meter
distance |
< 45dB |
< 50dB |
< 50dB |
< 45dB |
< 50dB |
< 50dB |
Communications |
DB-9 port |
RS-232 series interface |
Intelligent slot |
Options: SMNP card, AS400 card or winpower CMC/(USB port) |
Environment |
Operating
Tem. |
0~40º C |
Operating Humidity |
20~90% non-condensing |
Weight |
Net(kg) |
13 |
31.5 |
32 |
7 |
13.5 |
14 |
Dimensions(pkg) |
WxDxH
(mm) |
240*495*335 |
335*590*480 |
335*590*480 |
240*495*335 |
335*590*480 |
335*590*480 |