Model: 1kva/2kva/3kva/6kva/10kva/15kva/20kva

Application: 
Servers, Data-center, Critical network devices, Sensitive electrionic equipment, Telecom... 

Key Feature: 
1). Ture on-line double conversion technology with advanced microprocessor control 
2). Wide input voltage range 
3). Zero transfer time 
4). Protection against all type of power problems 
5). Self test while start of the UPS 
6). Site wiring fault warning 
7). On-battery power-on function 
8). Smart RS232 communication interface 
9). Intelligent slot available 
10). Sealed lead-acid, maintenance free battery 

Specfications:

Model   C1K C2K C3K C1KS C2KS C3KS
Capacity VA/W 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW 1KVA/0.7KW 2KVA/1.4KW 3KVA/2.1KW
Input Nominal voltage 110/115/120VAC or 220/230/240VAC
Voltage range 180~300VAC
Frequency range 50Hz: 46~54Hz;   60Hz: 56~64Hz
Phase Single phase
Power factor > 97%
Connection IEC320-10A IEC320-10A IEC320-16A IEC320-10A IEC320-10A IEC320-16A
Output Voltage 110/115/120VAC x(1+/-2%) or 220/230/240VAC x(1+/-2%)
Frequency Synchronization range(line mode); 50 or 60 x(1+/-0.2%)Hz (Battery mode)
Phase Single phase
Wave form Sine wave
Power factor 0.7
Voltage distortion 3% 4% 4% 3% 4% 4%
Overload capability 110%-150% for 30sec. ≥ 150% for 200ms
Current crest ratio 3: 1
Connections IEC320*4 IEC320*6 IEC320*3 IEC320*4 IEC320*6 IEC320*3
Battery Type Sealed, maintenance free, lead-acid
Nominal
DC voltage
      36VDC 96VDC 96VDC
Quantity 3pcs 8pcs 8pcs Depends on the requested back-up time
Back-up time(full load) 5min 9min 5min Depends on the capacity of the external battery bank
Recharge time 5hrs to 90% if capacity Depends on the capacity of the external battery bank
Automatic transfer On overload and UPS failure
Before UPS
power on
Default " ON' user adjustable to ' YES"
Voltage range 40~132VAC(default), user adjustable within 40~143VAC or 80~264VA(default), user adjustable within 80~286VAC
Transfer time AC to DC
zero
Inverter to bypass 4ms(typical)
Indicator LED display Load level/Battery level, Battery, Utility power, Inverter, Bypass, Overload, Fault
LCD display UPS status 1/P  0/P voltage frequency, Battery voltage, Battery capacity, loading, Temperature, History record
Audible alarm   Bypass, On battery mode, Battery low, Overload, Fault etc
Acoustic  noise At 1meter
distance
< 45dB < 50dB < 50dB < 45dB < 50dB < 50dB
Communications DB-9 port RS-232 series interface
Intelligent slot Options: SMNP card, AS400 card or winpower CMC/(USB port)
Environment Operating
Tem.
0~40º C
Operating Humidity 20~90% non-condensing
Weight Net(kg) 13 31.5 32 7 13.5 14
Dimensions(pkg) WxDxH
(mm)
240*495*335 335*590*480 335*590*480 240*495*335 335*590*480 335*590*480
Payment Terms︰T/T,L/C,Western union
Product Image



Related Products
Solar Charge Controller
Solar Charge Controller
US $ 10
Online Industry Low Frequency UPS
Online Industry Low Frequency UPS
US $ 1
PG Power Inverter Charger Family UPS 1000VA
PG Power Inverter Charger Family UPS 1000VA
US $ 30
Offline Backup UPS 1500VA
Offline Backup UPS 1500VA
US $ 20




Home  |  Product Catalog  |  News  |  Contact Us  |  Sitemap  |  Mobile Version

Powered by DIYTrade.com  Build your FREE website !